next up previous contents
Next: cwmax - WMM Parameter Up: Private (Driver Specific) Driver Previous: cwmin - WMM Parameter   Contents

get_cwmin - Get WMM $\mathrm{CW}_{\mathrm{min}}$ Parameter

Number of Input Arguments: 2
Number of Returned Arguments: 1
Default Value: N/A
Resets State Machine After Command: No
This command retrieves the $\mathrm{CW}_{\mathrm{min}}$ WMM parameter for either the AP or station parameter set. The get_cwmin command must be followed by 2 values. The first value is the access class (AC) number as defined in Table [*]. The second value indicates whether to retrieve the value from the AP or station parameter set. A value of 0 indicates the $\mathrm{CW}_{\mathrm{min}}$ is from the AP parameter set. A value of 1 indicates the $\mathrm{CW}_{\mathrm{min}}$ is from the station parameter set.
Example:The following command gets the $\mathrm{CW}_{\mathrm{min}}$ in the AP parameter set for the VI AC.
myprompt# iwpriv ath0 get_cwmin 2 0
ath0 get_cwmax:4



root 2005-12-16